| LHT 02/17 | LHT 08/17 |
Saggars with top lid
Spacers
Over-temperature limit controller
LHT 02/16 - LHT 08/18
The first-class workmanship using high-quality materials combined with ease of operation makes these models all-rounders for the dental laboratory. These chamber high-temperature furnaces are perfectly suited for the sintering of zirconia units. The open molybdenum-discilicide heating elements and the large volume of the furnace chamber provide for short process cycles and high throughput. The zirconia units are positioned in ceramic saggars. Up to three saggars can be stacked into the furnace. The top saggar should be covered by a lid in order to minimize the risk of contamination. The controller can be programmed for each individual zirconia material.
- Tmax 1600 °C, 1750 °C, or 1800 °C
- High-quality molybdenum disilicide heating elements
- Furnace chamber lined with first-class, durable fibre material
- Housing made of sheets of textured stainless steel
- Double-walled housing with additional fan cooling for low surface temperature
- Typical cycle time for zirconia firing at 1500 °C approx. 8 hours including cooling down
- Furnace sizes of 2, 4, or 8 liters
- With lift door, whereby the hot side is away from the operator
- Adjustable air inlet
- Exhaust air opening in the roof
- Type B thermocouple
- Switching system with phase-angle firing thyristors (SCRs)
Additional Equipment
- Over-temperature limit controller with manual reset for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the oven and load
- Square saggar for charging of up to three layers
- Spacer recommended to be placed under the bottom saggar for better temperature uniformity
- Protective gas connection
- Manual or automatic gas supply system
| Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions in mm | Power | Electrical | Weight | Max. number | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| °C | w | d | h | in L | W | D | H | kW | connection* | in kg | of crowns | |
| LHT 02/16 | 1600 | 90 | 150 | 150 | 2 | 470 | 700 | 750+350 | 3,0 | single-phase | 75 | 60 |
| LHT 04/16 | 1600 | 150 | 150 | 150 | 4 | 470 | 700 | 750+350 | 5,2 | 3-phase¹ | 85 | 90 |
| LHT 08/16 | 1600 | 150 | 300 | 150 | 8 | 470 | 850 | 750+350 | 8,0 | 3-phase¹ | 100 | 120 |
| LHT 02/17 | 1750 | 90 | 150 | 150 | 2 | 470 | 700 | 750+350 | 3,0 | single-phase | 75 | 60 |
| LHT 04/17 | 1750 | 150 | 150 | 150 | 4 | 470 | 700 | 750+350 | 5,2 | 3-phase¹ | 85 | 90 |
| LHT 08/17 | 1750 | 150 | 300 | 150 | 8 | 470 | 850 | 750+350 | 8,0 | 3-phase¹ | 100 | 120 |
| LHT 02/18 | 1800 | 90 | 150 | 150 | 2 | 470 | 700 | 750+350 | 3,6 | single-phase | 75 | 60 |
| LHT 04/18 | 1800 | 150 | 150 | 150 | 4 | 470 | 700 | 750+350 | 5,2 | 3-phase¹ | 85 | 90 |
| LHT 08/18 | 1800 | 150 | 300 | 150 | 8 | 470 | 850 | 750+350 | 9,0 | 3-phase¹ | 100 | 120 |
| ¹Heating only between two phases *Please see page 14 for more information about mains voltage | ||||||||||||